Circuit Breakers

The deepest part of the index — miniature, moulded case and plug-on breakers, with interrupting capacity and trip curve data on every entry.

Part Number
Category catalogCircuit BreakersThe deepest part of the index — miniature, moulded case and plug-on breakers, with interrupting capacity and trip curve data on every entry. 12,150parts 19brands 15fields indexed Search specifications
Indexed parts — showing 12 of 12150
1492-CB3G200
1492-CB3G200 Indexed
Allen Bradley · Supplementary Protector · Allen-Bradley 1492-CB3G200 Circuit Breaker | 480V 20A 3P 10kA@125V Feed-Thru Bulletin 1492-CB
Poles: 3Continuous Current Rating: 20Voltage Rating: 480 VInterrupting Capacity (AIC): 10 kA at 125V
15/15 fields indexed
1492-CB3H050
1492-CB3H050 Indexed
Allen Bradley · Supplementary Protector · Allen-Bradley 1492-CB3H050 Circuit Breaker | 480V 5A 3P 10kA@125V Feed-Thru Bulletin 1492-CB
Poles: 3Continuous Current Rating: 5Voltage Rating: 480 VInterrupting Capacity (AIC): 10 kA at 125V
15/15 fields indexed
1492-CB3H070
1492-CB3H070 Indexed
Allen Bradley · Supplementary Protector · Allen-Bradley 1492-CB3H070 Circuit Breaker | 480V 7A 3P 10kA@125V Feed-Thru Bulletin 1492-CB
Poles: 3Continuous Current Rating: 7Voltage Rating: 480 VInterrupting Capacity (AIC): 10 kA at 125V
15/15 fields indexed
1492-CB3H250
1492-CB3H250 Indexed
Allen Bradley · Supplementary Protector · Allen-Bradley 1492-CB3H250 Circuit Breaker | 480V 25A 3P 10kA@125V Feed-Thru Bulletin 1492-CB
Poles: 3Continuous Current Rating: 25Voltage Rating: 480 VInterrupting Capacity (AIC): 10 kA at 125V
15/15 fields indexed
1492-MCGAT115
1492-MCGAT115 Indexed
Allen Bradley · Ground Fault Circuit Breaker · Allen-Bradley 1492-MCGAT115 Molded Case Circuit Breaker
Poles: 1Continuous Current Rating: 15Voltage Rating: 120 VACInterrupting Capacity (AIC): —
13/15 fields indexed
1492CB2G010
1492CB2G010 Indexed
Allen Bradley · Supplementary Protector · Allen-Bradley 1492CB2G010 Circuit Breaker | 1492 Series 1492 480V 1A
Poles: 2Continuous Current Rating: 1Voltage Rating: 480 VInterrupting Capacity (AIC): 10 kA at 480V
14/15 fields indexed
1492GH050
1492GH050 Indexed
Allen Bradley · Supplementary Protector · Allen-Bradley 1492-GH050 Circuit Breaker | 240V 5A 1 pole Feed-Thru Thermal Magnetic
Poles: 1Continuous Current Rating: 5Voltage Rating: 240 VInterrupting Capacity (AIC): —
14/15 fields indexed
1492GH100
1492GH100 Indexed
Allen Bradley · Supplementary Protector · Allen-Bradley 1492GH100 Molded Case Circuit Breaker
Poles: 1Continuous Current Rating: 10Voltage Rating: 240 VInterrupting Capacity (AIC): —
14/15 fields indexed
2B125
2B125 Indexed
Federal Pacific · Federal Pacific 2B125 Circuit Breaker | 240V 125A 2P 10kA@240V 2B Series
Poles: 2Continuous Current Rating: 125Voltage Rating: 240 VInterrupting Capacity (AIC): 10 kA at 240V
15/15 fields indexed
2B150
2B150 Indexed
Federal Pacific · Federal Pacific 2B150 Circuit Breaker | 240V 150A 2P 10kA@240V 2B Series
Poles: 2Continuous Current Rating: 150Voltage Rating: 240 VInterrupting Capacity (AIC): 10 kA at 240V
14/15 fields indexed
2B200
2B200 Indexed
Federal Pacific · Federal Pacific 2B200 Circuit Breaker | 240V 200A 2P 10kA@240V Bolt-On 2B Series
Poles: 2Continuous Current Rating: 200Voltage Rating: 240 VInterrupting Capacity (AIC): 10 kA at 240V
15/15 fields indexed
2P100FED
2P100FED Indexed
Federal Pioneer · Federal Pioneer 2P100FED Circuit Breaker | 240V 100A 2P 10kA@120V Plug-In Stab-Lok
Poles: 2Continuous Current Rating: 100Voltage Rating: 240 VInterrupting Capacity (AIC): 10 kA at 120V
14/15 fields indexed
0 selected — select 2–4 parts