Part Number
You searched for KXT5CUAL2X500K-3PC ABB · Circuit Breakers · ABB KXT5CUAL2X500K-3PC Molded Case Circuit Breaker 100candidates 4brands 15fields checked
Ranked matches — showing 76–100 of 100
3VA5160-6ED31-0AA0
3VA5160-6ED31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 60Voltage Rating: 600 VInterrupting Capacity (AIC): 65 kA at 480V
64%9/14 fields
3VA5160-6EF31-0AA0
3VA5160-6EF31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 125Voltage Rating: 480 VInterrupting Capacity (AIC): 65 kA at 480V
64%9/14 fields
3VA5170-4EC31-0AA0
3VA5170-4EC31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 70Voltage Rating: 600 VInterrupting Capacity (AIC): 25 kA at 480V
64%9/14 fields
3VA5170-4ED31-0AA0
3VA5170-4ED31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 125Voltage Rating: 480 VInterrupting Capacity (AIC): 25 kA at 480V
64%9/14 fields
3VA5170-4EF31-0AA0
3VA5170-4EF31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 70Voltage Rating: 480 VInterrupting Capacity (AIC): 25 kA at 480V
64%9/14 fields
3VA5170-5EC31-0AA0
3VA5170-5EC31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 70Voltage Rating: 600 VInterrupting Capacity (AIC): 35 kA at 480V
64%9/14 fields
3VA5170-5ED31-0AA0
3VA5170-5ED31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 70Voltage Rating: 600 VInterrupting Capacity (AIC): 35 kA at 480V
64%9/14 fields
3VA5170-5EF31-0AA0
3VA5170-5EF31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 70Voltage Rating: 480 VInterrupting Capacity (AIC): 35 kA at 480V
64%9/14 fields
3VA5170-6EC31-0AA0
3VA5170-6EC31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 70Voltage Rating: 600 VInterrupting Capacity (AIC): 65 kA at 480V
64%9/14 fields
3VA5170-6ED31-0AA0
3VA5170-6ED31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 70Voltage Rating: 600 VInterrupting Capacity (AIC): 65 kA at 480V
64%9/14 fields
3VA5180-4EC31-0AA0
3VA5180-4EC31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 80Voltage Rating: 600 VInterrupting Capacity (AIC): 25 kA at 480V
64%9/14 fields
3VA5180-5EC31-0AA0
3VA5180-5EC31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 80Voltage Rating: 690 VInterrupting Capacity (AIC): 35 kA at 480V
64%9/14 fields
3VA5180-5ED31-0AA0
3VA5180-5ED31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 80Voltage Rating: 600 VInterrupting Capacity (AIC): 35 kA at 480V
64%9/14 fields
3VA5180-5EF31-0AA0
3VA5180-5EF31-0AA0 Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 80Voltage Rating: 600 V; 690 VInterrupting Capacity (AIC): 35 kA at 480V
64%9/14 fields
CRD316T33W Compatible alternative
Eaton · Circuit Breakers
Poles: 3Continuous Current Rating: 1600Voltage Rating: 600 VInterrupting Capacity (AIC): 65 kA at 480V
64%9/14 fields
RGH316032E
RGH316032E Compatible alternative
Eaton · Circuit Breakers
Poles: 3Continuous Current Rating: 1600Voltage Rating: 600 VInterrupting Capacity (AIC): 65 kA at 480V
64%9/14 fields
SPD69160NT
SPD69160NT Compatible alternative
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 1600Voltage Rating: 600 VInterrupting Capacity (AIC): 35 kA at 480V
64%9/14 fields
3VA4170-5ED34-0AA0
3VA4170-5ED34-0AA0 Smart substitute
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 70Voltage Rating: 600 VInterrupting Capacity (AIC): 35 kA at 480V
57%8/14 fields
3VA5110-4ED31-0AA0
3VA5110-4ED31-0AA0 Smart substitute
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 100Voltage Rating: 480 VInterrupting Capacity (AIC): 25 kA at 480V
57%8/14 fields
3VA5110-6ED31-0AA0
3VA5110-6ED31-0AA0 Smart substitute
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 100Voltage Rating: 600 VInterrupting Capacity (AIC): 65 kA at 480V
57%8/14 fields
3VA5110-6EF31-0AA0
3VA5110-6EF31-0AA0 Smart substitute
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 100Voltage Rating: 690 VInterrupting Capacity (AIC): 65 kA at 480V
57%8/14 fields
3VA5120-4ED31-0AA0
3VA5120-4ED31-0AA0 Smart substitute
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 20Voltage Rating: 690 VInterrupting Capacity (AIC): 65 kA at 480V
57%8/14 fields
3VA5120-6ED31-0AA0
3VA5120-6ED31-0AA0 Smart substitute
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 20Voltage Rating: 600 VInterrupting Capacity (AIC): 65 kA at 480V
57%8/14 fields
3VA5150-4ED31-0AA0
3VA5150-4ED31-0AA0 Smart substitute
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 50Voltage Rating: 480 VInterrupting Capacity (AIC): 25 kA at 480V
57%8/14 fields
3VA5160-4ED31-0AA0
3VA5160-4ED31-0AA0 Smart substitute
Siemens · Circuit Breakers
Poles: 3Continuous Current Rating: 60Voltage Rating: 600 VInterrupting Capacity (AIC): 25 kA at 480V
57%8/14 fields
0 selected — pick an alternative