Part Number
You searched for TEDUV9 ABB · Accessory · General Electric TEDUV9 Circuit Breaker Under Voltage Release | 48V TE Series 100candidates 6brands 15fields checked
Ranked matches — showing 26–50 of 100
BARP070
BARP070 Compatible alternative
Square D · Accessory
UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)Trip Unit Technology: Electronic / Solid State
86%12/14 fields
BARP080
BARP080 Compatible alternative
Square D · Accessory
UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)Trip Unit Technology: Electronic / Solid State
86%12/14 fields
BARP083
BARP083 Compatible alternative
Square D · Accessory
UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)Trip Unit Technology: Electronic / Solid State
86%12/14 fields
BE-SRPG600A500
BE-SRPG600A500 Compatible alternative
ABB · Accessory
Continuous Current Rating: 500UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)
86%12/14 fields
BRSF125
BRSF125 Compatible alternative
Eaton · Accessory
Continuous Current Rating: 125Voltage Rating: 240 VACUL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)
86%12/14 fields
GTP0100U0103
GTP0100U0103 Compatible alternative
ABB · Accessory
Continuous Current Rating: 100UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)
86%12/14 fields
N250X
N250X Compatible alternative
Siemens · Accessory
Continuous Current Rating: 250UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)
86%12/14 fields
1288C74G03
1288C74G03 Compatible alternative
Eaton · Accessory
Continuous Current Rating: 6Voltage Rating: 240 VUL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)
79%11/14 fields
1300T
1300T Compatible alternative
Federal Pacific · Accessory
Continuous Current Rating: 225Voltage Rating: 600 VUL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)
79%11/14 fields
1371D72G22
1371D72G22 Compatible alternative
Eaton · Accessory
Voltage Rating: 32 VInterrupting Capacity (AIC): Matches MC series breakers (typically 10 kAUL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)
79%11/14 fields
1373D62G01
1373D62G01 Compatible alternative
Eaton · Accessory
Poles: 3Voltage Rating: 120 VUL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)
79%11/14 fields
140G-M-TLC23
140G-M-TLC23 Compatible alternative
Allen Bradley · Accessory
Poles: 3UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)
79%11/14 fields
20PCG1600
20PCG1600 Compatible alternative
Eaton · Accessory
Continuous Current Rating: 1600UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)
79%11/14 fields
4LC400
4LC400 Compatible alternative
Eaton · Accessory
Continuous Current Rating: 400UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)
79%11/14 fields
6LC500
6LC500 Compatible alternative
Eaton · Accessory
Continuous Current Rating: 500UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)
79%11/14 fields
A8MC600
A8MC600 Compatible alternative
Eaton · Accessory
Continuous Current Rating: 600Voltage Rating: 600 VUL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)
79%11/14 fields
AMC6EB
AMC6EB Compatible alternative
ABB · Accessory
Poles: 6Continuous Current Rating: 300Voltage Rating: 600 VUL 489 Compliant: Yes
79%11/14 fields
AMC6EYFP
AMC6EYFP Compatible alternative
ABB · Accessory
Poles: 6Continuous Current Rating: 100Voltage Rating: 480 VUL 489 Compliant: Yes
79%11/14 fields
AMC6FJFP
AMC6FJFP Compatible alternative
ABB · Accessory
Poles: 3Continuous Current Rating: 250Voltage Rating: 600 VUL 489 Compliant: Yes
79%11/14 fields
ARP060
ARP060 Compatible alternative
Square D · Accessory
Continuous Current Rating: 4000UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)RoHS Compliant: Exempt (not in RoHS scope)
79%11/14 fields
ARP075
ARP075 Compatible alternative
Square D · Accessory
Continuous Current Rating: 4000Voltage Rating: 600 VACUL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)
79%11/14 fields
BE-SRPK800A800
BE-SRPK800A800 Compatible alternative
ABB · Accessory
Poles: 3Continuous Current Rating: 800Voltage Rating: 600 VACUL 489 Compliant: Yes
79%11/14 fields
PDG3X3TA400
PDG3X3TA400 Compatible alternative
Eaton · Accessory
Poles: 3Continuous Current Rating: 400Voltage Rating: 600 VUL 489 Compliant: Yes
79%11/14 fields
PDG3X3TA401H
PDG3X3TA401H Compatible alternative
Eaton · Accessory
Poles: 3Continuous Current Rating: 400UL 489 Compliant: YesIEC 60947-2 Tested: Not separately IEC-tested (UL/CSA MCCB)
79%11/14 fields
PWNF250-AM
PWNF250-AM Compatible alternative
Eaton · Accessory
Poles: 3Continuous Current Rating: 200Voltage Rating: 240 VUL 489 Compliant: Yes
79%11/14 fields
0 selected — pick an alternative